CÔNG TY CỔ PHẦN SUBIN VINA
VPGD: P216, Tòa nhà Kim Ánh, Số 1 ngõ 78 Duy Tân, Cầu Giấy, HN
 Hot line: +84 986 117 188
logo
7577156_3
Hỗ trợ trực tuyến

 

TECHNICAL SALES

Sales 1: 0988 238018

tuananh@subinvina.com

 

Sales 2: 0964 643758

nguyencuong@subinvina.com

 

 

 CUSTOMER SUPPORT

0944 297863

support@subinvina.com

Water Cooled Jumper / Sub Cable

Water Cooled Jumper / Sub Cable
water-cooled-jumper/sub-cable - ảnh nhỏ  1 water-cooled-jumper/sub-cable - ảnh nhỏ 2 water-cooled-jumper/sub-cable - ảnh nhỏ 3

Water Cooled Jumper / Sub Cable

Mã sản phẩm: Water Cooled Jumper / Sub Cable
Hãng sản xuất: Electromech
Xuất xứ: India

Để lại số điện thoại

Lượt xem 54

Kho hàng: 0

Resistance checking of Aid/Sub Cable Water - Cooled Aid/Sub Cable Final Packing Process
Resistance checking of Aid/Sub Cable Water - Cooled Aid/Sub Cable Final Packing Process
 
 
Specification of Water Cooled Jumper / Sub Cable :
1. Design of Cable as per Customers Specification with very less tolerance.
2. Special type of rubber hose with the High flexibility, more than 10 Kg/cm2
Capacity and to protect to high temperature water for safe operation. Excellent cooling effect even in continued welding operation.
3. Copper wire size is 33 Gauge for 300 MCM & 400 MCM as per standard of RWMA.
4. Accurate copper straight lugs or copper bend lug with 99% conductivity of Electrolytic Copper. Little Impedance & little Reactance drop.
5. Fantastic water testing units with Pressure 10 to 12 Kg/cm2, each and every Cable are tested.
6. Good Quality product with Long Life and very competitive rate. Long cable life reduces cable cost per weld - the true measure of cost cable.
7.

We have good team of engineers with more than 10 Years experience in same field.

8. Strict Quality Control during production, delivery as per schedule.
9. Easy for check & replacement & maintenance.
10. We have own Quality Assurance Plan of our products.
 

Water Cooled Jumpers (WJ) come equipped with full length filter tubes, to insure the free flow of water through the entire cable. Bending or kinking will not reduce water flow.

To order cables you need to determine: 1] Type of end 2] Cable Gauge 3] Length
A chart for sizing the correct gauge cable is on the right of the page, as well as guidelines for installation.

 
Water Cooled Jumper End Styles
Type B

MCM

A

B

C

350/400

9/16″

1-15/16″

9/16″

500/600

9/16″

1-15/16″

5/8″

750

5/8″

1-3/8″

11/16″

1000

3/4″

1-1/2″

3/4″

Type B - 2

MCM

A

B

C

D

350/400

11/16″

1-1/16″

2-11/16″

17/32″

500/600

13/16″

1-3/8″

2-7/8″

17/32″

750

13/16″

1-5/8″

3-1/8″

21/32″

1000

15/16″

1-7/8″

3-1/4″

21/32″



Type B-4

MCM

A

B

350/400

1-3/8″

1/2″

500/600

1-7/8″

5/8″

750

1-7/8″

5/8″

1000

2″

11/16″
Type B - 5

MCM

A

B

C

D

350/400

9/16″

1-1/8″

1-1/4″

1/2″

500/600

5/8″

1-1/4″

1-3/8″

5/8″

750

5/8″

1-3/8″

1-3/8″

5/8″

1000

5/8″

1-5/8″

1-3/8″

5/8″



Type B-6

MCM

A

B

350/400

9/16″

1-1/8″

500/600

5/8″ 1-1/4″

750

5/8″ 1-3/8″

1000

5/8″ 1-5/8″
Type B-6 2Hole

MCM

A

B

350/400

9/16″

1-1/8″

500/600

5/8″ 1-1/4″

750

5/8″ 1-3/8″

1000

5/8″ 1-5/8″


Type B-7

MCM

A

B

350/400

9/16″

1-1/8″

500/600

5/8″ 1-1/4″

750

5/8″ 1-3/8″

1000

5/8″ 1-5/8″
Type B-7

MCM

A

B

B

350/400

9/16″

2-1/8″

17/32″

500/600

9/16″ 2-1/8″ 17/32″

750

9/16″ 2-5/16″ 21/32″

1000

5/8″ 2-3/8″ 21/32″
   
 
Type B-11

MCM

A

B C

D

350/400

3/8″ 2″ 1-1/8″

9/16″

500/600

3/8″ 2″ 1-1/8″ 9/16″

750

5/8″ 2-1/2″ 1-1/2″ 7/8″

1000

3/4″ 2-1/2″ 1-1/2″ 7/8″
 
 

Water Cooled Jumper Sizing

Use the following method to determine what size cable should be used for your application. First you use the Conversion Factor chart to determine your “Continuous Duty Current”; then you read the correct size cable off the second chart. An example is worked out below.

Step 1: Lay one side of a straight edge across the graph at the six cycles of current “one time” point (the left hand vertical scale of the conversion factor chart).

Step 2: Pivot the other end of the straight edge across to line up with the “60 welds per minute” on the far right vertical scale.

Step 3: At the intersection of your straight edge with the diagonal conversion factor scale line, you should be able to read a conversion factor of .32 off the lower 1/2 of the line.

Step 4: Multiply the required current (60,000 amps) by the conversion factor (.32) to get the “continuous duty current” of 19,200 amps. Now proceed to the Water Cooled Jumper Selection Chart to read complete the selection.

Step 5: Line up your straight edge on the 19,200 continuous duty amp mark, and find the intersection with your desired length line (from below, we want 60 inches).

Step 6: Any cable whose line is above this point may be safely used, since the load it would carry will be within its thermal capacity. In our case the 1000 MCM cable would be the best match, and will not exceed the design specifications of the jumper cable.

Example Data:
6 cycles of current “on time” per weld
60 welds per minute
60,000 amps per weld
5 ft cable Length

 

Good Working shapes for Water Cooled Cables

Installation Guidelines

How to install water cooled cables

Water cooled jumpers should always be installed with a bend radii ranging from 90° to 180°. See the chart below for the minimum recommended radii.

It should be noted that jumper life is inversely related to the operating temperature of the cable; the higher the temperature the shorter the life. The recommended operating temperature is 131°F (55°C) or less, and the maximum operating temperatures should not exceed 158°F (70°C). Making sure there is enough water flow is critical for insuring a low operating temperature.

 

Recommended Minimum Bend Radii:
350 MCM – 400 MCM: 2″
500 MCM – 600 MCM: 3″
750 MCM – 1000 MCM: 4″

Minimum Distance from the end of the hose to the point where the bend radii should start is:
350 MCM – 400 MCM: 2-1/2″
500 MCM – 600 MCM: 3″
750 MCM – 1000 MCM: 3-1/2″


More Specifications
D.C. Resistance of Single Conductor Water Cooled
(and Air Cooled) Cables

MCM D.C. Resistance
(Ohms per foot at 70 °C)
350 .0000376
400 .0000322
500 .0000263
600 .0000217
750 .0000172
1000 .0000130
1200 .0000110
1500 .0000088
2000 .0000066

 


Recommended Minimum Gallons/min
WJ (single conductor). . . .2 GPM
UT (dual conductor) . . . .2-1/2 GPM
Liên hệ

CÔNG TY CỔ PHẦN SUBIN VINA

Địa chỉ: Số 415, phố Thanh Bình , Phường Mộ Lao, Quận Hà Đông, Thành phố Hà Nội, Việt Nam

VPGD: Phòng 216, Tòa nhà Kim Ánh, Số 1 ngõ 78 Duy Tân, Cầu Giấy, Hà Nội

Phone: +84 24 629 15 369

Mobile: +84 986 117 188

Email: support@subinvina.com

Fanpage